<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Medium-voltage UPS and energy management for AI data centers on Battalion Energy</title><link>https://battalion.energy/</link><description>Recent content in Medium-voltage UPS and energy management for AI data centers on Battalion Energy</description><generator>Hugo</generator><language>en-US</language><lastBuildDate>Thu, 08 Oct 2026 00:00:00 +0000</lastBuildDate><atom:link href="https://battalion.energy/index.xml" rel="self" type="application/rss+xml"/><item><title>AI data centers. Critical power at medium voltage.</title><link>https://battalion.energy/solutions/ai-data-centers/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/ai-data-centers/</guid><description>Battery control between a changing compute load and the grid.</description></item><item><title>Battalion EMS</title><link>https://battalion.energy/products/ems/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/ems/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;SITE CONTROL&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;One supervisory loop across the plant.&lt;/h2&gt;&#10; &lt;p&gt;Battalion EMS is the site energy management system. Its supervisory loop runs once per second, coordinating plant dispatch and equipment limits. The medium-voltage uninterruptible power supply (UPS) has a separate UPS block controller for its local response.&lt;/p&gt;&#10;&lt;p&gt;&lt;a href="https://battalion.energy/products/scada/"&gt;Supervisory control and data acquisition (SCADA)&lt;/a&gt; runs on the EMS controller. It collects field values with their timestamps and quality, assigns command-point authority and records every tag in the on-site historian. &lt;a href="https://battalion.energy/products/live/"&gt;Battalion Live&lt;/a&gt; receives the backlog when the wide-area link returns.&lt;/p&gt;</description></item><item><title>Modeling and optimization.</title><link>https://battalion.energy/services/modeling-and-optimization/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/services/modeling-and-optimization/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / ANALYSIS&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Advanced modeling across the full operating duty.&lt;/h2&gt;&#10; Battalion uses the Energence energy intelligence platform for these studies. A storage project can serve a load and a market at the same time. Battalion models both sides of the meter together, including the energy held for backup and the battery life each dispatch consumes.&#10; &lt;ul class="modeling-list"&gt;&lt;li&gt;Scenario analysis across four coincident peaks (4CP), five coincident peaks (5CP) and twelve coincident peaks (12CP).&lt;/li&gt;&lt;li&gt;Energy arbitrage and ancillary services by market.&lt;/li&gt;&lt;li&gt;Front-of-the-meter and behind-the-meter economics in one model.&lt;/li&gt;&lt;li&gt;Tariff-accurate bill simulation.&lt;/li&gt;&lt;li&gt;Power smoothing, ramp rate and ride-through simulation at millisecond resolution.&lt;/li&gt;&lt;li&gt;Sizing and duration optimization.&lt;/li&gt;&lt;li&gt;Battery life and degradation curves.&lt;/li&gt;&lt;li&gt;Warranty-constraint modeling.&lt;/li&gt;&lt;li&gt;Eight North American markets modeled, with an operating fleet in ERCOT, CAISO and Mexico.&lt;/li&gt;&lt;/ul&gt;&#10;&#10; &lt;div class="market-coverage"&gt;&lt;p class="eyebrow"&gt;EIGHT NORTH AMERICAN MARKETS&lt;/p&gt;</description></item><item><title>Battalion Live</title><link>https://battalion.energy/products/live/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/live/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / SITE VISIBILITY&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;One site. State and history together.&lt;/h2&gt;&#10; Battalion Live brings operating data into one workspace. The site dashboard shows photovoltaic (PV) power, battery state of charge (SOC), metered demand and inverter state across four-day timelines. Operators can read the present condition alongside the changes that led to it.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / NOTIFICATIONS&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;The alarm reaches the operating team.&lt;/h2&gt;&#10; Notification triggers connect a measured condition with the people responsible for it. For example, a low battery SOC alarm can notify a named group of operators.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;03 / CONNECTED OPERATION&lt;/p&gt;</description></item><item><title>Engineering and integration.</title><link>https://battalion.energy/services/engineering-and-integration/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/services/engineering-and-integration/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / HARDWARE&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Integrated skids and auxiliary power distribution.&lt;/h2&gt;&#10; &lt;p&gt;Integrated skids bring the required equipment interfaces into a defined assembly. Auxiliary power distribution supplies the controls and supporting equipment, with two sources where the critical-power design requires them.&lt;/p&gt;&#10;&lt;p&gt;Control panels bring together sub-block controllers, network interfaces and power distribution. Controller pairing and power-source changeover follow the system availability design.&lt;/p&gt;&#10;&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / INTERFACES&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Protocol integration and plant control.&lt;/h2&gt;&#10; &lt;p&gt;Battery management systems, power conversion systems (PCS), switchgear and meters need agreed data models and command priorities. Battalion develops equipment mappings, handles communication loss and checks control behavior before site operation.&lt;/p&gt;</description></item><item><title>Factories and industrial power.</title><link>https://battalion.energy/solutions/factories-and-industrial/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/factories-and-industrial/</guid><description>Protect process loads and manage the industrial tariff.</description></item><item><title>Coincident-peak programs.</title><link>https://battalion.energy/solutions/coincident-peak-programs/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/coincident-peak-programs/</guid><description>Size and dispatch for the intervals that set the charge.</description></item><item><title>Energence</title><link>https://battalion.energy/products/energence/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/energence/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;THE PLATFORM&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;An energy intelligence platform, powered by Battalion&amp;#39;s battery optimizer.&lt;/h2&gt;&#10; &lt;p&gt;Energence is Battalion&amp;rsquo;s energy intelligence platform. It is powered by our battery optimizer, the engine that sizes, dispatches and values a battery against tariffs, market programs and battery life.&lt;/p&gt;&#10;&lt;p&gt;Behind it is what we have accumulated since 2016: more than 10 TB of market, grid and site data, covering more than 25 power markets across the Americas, Europe, Asia and Australia, with their market rules, a utility tariff database and live data streaming from the grid operators. AI price and load forecasting and bid optimization run on top.&lt;/p&gt;</description></item><item><title>Co-located generation.</title><link>https://battalion.energy/solutions/co-located-generation/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/co-located-generation/</guid><description>Coordinate generation, storage and load at one connection.</description></item><item><title>Battalion SCADA</title><link>https://battalion.energy/products/scada/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/scada/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / FIELD DATA&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Every value carries its context.&lt;/h2&gt;&#10; &lt;p&gt;Battalion SCADA polls power conversion systems (PCS), battery management systems, meters, protection relays, remote input/output (I/O) and fire panel contacts over Modbus TCP and RTU. These are the network and serial forms of Modbus. It reads relays and remote terminal units (RTUs) over Distributed Network Protocol 3 (DNP3).&lt;/p&gt;&#10;&lt;p&gt;Every value carries a timestamp, quality, units and limits. That context stays with the measurement so the operator can distinguish a current reading from a stale or invalid value.&lt;/p&gt;</description></item><item><title>Microgrids and critical power.</title><link>https://battalion.energy/solutions/microgrids-and-critical-power/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/microgrids-and-critical-power/</guid><description>Coordinate the island and hold the energy it needs.</description></item><item><title>Battalion power plant controller</title><link>https://battalion.energy/products/ppc/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/ppc/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / THE CONNECTION&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Plant control follows the interconnection limits.&lt;/h2&gt;&#10; &lt;p&gt;The point of interconnection (POI) is the boundary where the plant meets the grid. Battalion PPC controls active power, reactive power, frequency response and export limits at that boundary.&lt;/p&gt;&#10;&lt;p&gt;The plant command must fit both the interconnection agreement and the equipment available to deliver it. &lt;a href="https://battalion.energy/products/ems/"&gt;Battalion EMS&lt;/a&gt; coordinates the site through a supervisory loop that runs once per second.&lt;/p&gt;&#10;&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / INVERTER GROUPS&lt;/p&gt;</description></item><item><title>Front-of-the-meter storage.</title><link>https://battalion.energy/solutions/front-of-the-meter-storage/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/front-of-the-meter-storage/</guid><description>Connect market dispatch to local plant control.</description></item><item><title>Behind-the-meter storage and demand response.</title><link>https://battalion.energy/solutions/behind-the-meter-and-demand-response/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/behind-the-meter-and-demand-response/</guid><description>Dispatch storage against the bill and the program.</description></item><item><title>NOGRR 282 ride-through for AI data centers.</title><link>https://battalion.energy/solutions/nogrr-282-ride-through/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/nogrr-282-ride-through/</guid><description>Stay connected through a grid fault. Fully compatible with ERCOT NOGRR 282.</description></item><item><title>Data center power smoothing for AI loads.</title><link>https://battalion.energy/solutions/data-center-power-smoothing/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/data-center-power-smoothing/</guid><description>The battery takes every AI load pulse. The grid sees a flat draw.</description></item><item><title>Data center interconnection with a battery.</title><link>https://battalion.energy/solutions/data-center-interconnection/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/data-center-interconnection/</guid><description>Meet the utility&amp;rsquo;s conditions and move the interconnection forward.</description></item><item><title>Critical power for factories. Zero transfer time at medium voltage.</title><link>https://battalion.energy/solutions/critical-power-for-factories/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/solutions/critical-power-for-factories/</guid><description>Keep the process line running through outages and sags, with 0 ms transfer.</description></item><item><title>Critical power for factories in Mexico</title><link>https://battalion.energy/blog/critical-power-for-factories-in-mexico/</link><pubDate>Thu, 08 Oct 2026 00:00:00 +0000</pubDate><guid>https://battalion.energy/blog/critical-power-for-factories-in-mexico/</guid><description>&lt;p&gt;A factory in Mexico should plan for its grid supply to be interrupted. A battery-based uninterruptible power supply (UPS) at medium voltage answers that: it feeds the critical process through its own converter, with 0 ms transfer, so the line keeps running through an outage or a sag.&lt;/p&gt;&#10;&lt;h2 id="what-the-public-record-says"&gt;What the public record says&lt;/h2&gt;&#10;&lt;p&gt;Mexico&amp;rsquo;s central bank asked manufacturers with more than 100 workers whether their regular electricity supply had been interrupted in the previous 12 months. In the south, 81.6 percent said yes. In the central region it was 55.0 percent and in the north 49.7 percent. The figures are from Banco de México&amp;rsquo;s regional survey, as cited in the &lt;a href="https://www.bbvaresearch.com/wp-content/uploads/2024/09/Eng-Encuesta-BBVA-AMPIP-2024.pdf"&gt;BBVA Research and AMPIP nearshoring survey of September 2024&lt;/a&gt;.&lt;/p&gt;</description></item><item><title>ERCOT's proposed 10 MW power variation limit for AI data centers</title><link>https://battalion.energy/blog/ercot-10-mw-power-variation-limit-for-ai-data-centers/</link><pubDate>Mon, 05 Oct 2026 00:00:00 +0000</pubDate><guid>https://battalion.energy/blog/ercot-10-mw-power-variation-limit-for-ai-data-centers/</guid><description>&lt;p&gt;ERCOT has proposed a power variation limit for large computational loads. The peak-to-peak change in a site&amp;rsquo;s active power, filtered to keep everything from 0.1 Hz to 55 Hz, may not exceed 10 MW in any rolling 5-second window. ERCOT presented the proposal to its Large Load Working Group in February, April and June 2026 and said it would file the revision request in the second quarter of 2026. As of October 5, 2026 no revision request carrying the limit appears in ERCOT&amp;rsquo;s list of pending requests, so the limit is a proposal and its final wording can still change.&lt;/p&gt;</description></item><item><title>Why data centers must now ride through grid faults</title><link>https://battalion.energy/blog/why-data-centers-must-ride-through-grid-faults/</link><pubDate>Mon, 05 Oct 2026 00:00:00 +0000</pubDate><guid>https://battalion.energy/blog/why-data-centers-must-ride-through-grid-faults/</guid><description>&lt;p&gt;On July 22, 2026, at 7:56 in the morning, a 230 kV transmission line in Northern Virginia faulted. The protection cleared it as designed. Within about a minute, approximately 3,800 MW of data center load had moved off the grid and onto backup power, the largest load transfer PJM has recorded. PJM had seen similar events in the same area in July 2024 and February 2025, and this one was about twice as large.&lt;/p&gt;</description></item><item><title>Why your AI data center needs a battery</title><link>https://battalion.energy/blog/why-a-battery-for-your-ai-data-center/</link><pubDate>Fri, 02 Oct 2026 00:00:00 +0000</pubDate><guid>https://battalion.energy/blog/why-a-battery-for-your-ai-data-center/</guid><description>&lt;p&gt;An AI data center presents two power problems at once. Graphics processing unit (GPU) and tensor processing unit (TPU) clusters can swing tens of percent of facility load in under a second, every 20 seconds or so, thousands of times a day. The grid sees those changes at the connection. The compute equipment also depends on continuity of supply. A voltage sag that trips rack power supplies forces training to restart from its last checkpoint.&lt;/p&gt;</description></item><item><title>Careers in energy systems.</title><link>https://battalion.energy/careers/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/careers/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;THE PLATFORM&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;What you would be building on.&lt;/h2&gt;&#10; The platform is written in Rust and runs on real-time Linux at the site, where it controls batteries, power conversion systems, metering, protection relays, and microgrid controllers, and where it increasingly sits between the data center and the power system that feeds it. The architecture is modular: new capabilities are added as plugins and applications on a stable core, so the same platform serves a grid-scale battery, a critical-power microgrid, and an AI data center. It ships with an integrated user interface and connects to Battalion Live, which runs on AWS and handles telemetry, monitoring, and remote operations. Together they replace the SCADA and PLC control stack a conventional site would run, and they do more than that stack can: site control, power plant control, market dispatch, and monitoring in one system.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;JOIN THE TEAM&lt;/p&gt;</description></item><item><title>Contact Battalion Energy.</title><link>https://battalion.energy/contact/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/contact/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / PROJECTS&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Engineering review.&lt;/h2&gt;&#10; &lt;p&gt;Energy storage, medium-voltage uninterruptible power supply (UPS), site controls and integration. Start with the single-line diagram, the load profile and the operating requirement.&lt;/p&gt;&#10;&lt;p&gt;&lt;a href="mailto:contact@battalion.energy?subject=Engineering%20review"&gt;contact@battalion.energy&lt;/a&gt;&lt;/p&gt;&#10;&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / PLATFORM&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;A platform conversation around your project.&lt;/h2&gt;&#10; &lt;p&gt;Explore Battalion EMS for control, Battalion Live for monitoring and remote operations, or the Energence energy intelligence platform for project planning, energy data and modeling. Tell us which part of the project you are evaluating.&lt;/p&gt;</description></item><item><title>Dual-conversion medium-voltage UPS for AI data centers</title><link>https://battalion.energy/labs/ups-block/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/labs/ups-block/</guid><description/></item><item><title>Energy, in layers.</title><link>https://battalion.energy/labs/exploded-view/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/labs/exploded-view/</guid><description/></item><item><title>Medium-voltage UPS for AI data centers.</title><link>https://battalion.energy/products/mv-ups/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/products/mv-ups/</guid><description>Parallel and dual conversion on one platform.</description></item><item><title>Privacy policy.</title><link>https://battalion.energy/privacy/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/privacy/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / WHO WE ARE&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Battalion Energy, Inc. is the controller.&lt;/h2&gt;&#10; Battalion Energy, Inc., 1000 Main Street, Suite 2300, Houston, Texas 77002, United States, operates this website and decides how the data described here is used. Questions and requests go to &lt;a href="mailto:contact@battalion.energy"&gt;contact@battalion.energy&lt;/a&gt;.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / WHAT WE COLLECT&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Form entries, usage data and cookies.&lt;/h2&gt;&#10; &lt;p&gt;Forms. When you request information, request the spec sheet or sign up for updates, we collect what you type: name, company, company email address, what you are evaluating, and your consent to be contacted. Submissions from personal email providers are declined before anything is stored.&lt;/p&gt;</description></item><item><title>Spec sheet for the medium-voltage UPS.</title><link>https://battalion.energy/spec-sheet/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/spec-sheet/</guid><description>&lt;p&gt;The spec sheet covers parallel and dual-conversion connections, ride-through, control power, interfaces and the system availability design basis. Configuration details follow the site’s distribution and operating duty.&lt;/p&gt;&#10;&lt;p&gt;&lt;a href="https://battalion.energy/products/mv-ups/"&gt;Explore the medium-voltage UPS&lt;/a&gt; or &lt;a href="https://battalion.energy/contact/"&gt;talk to an engineer&lt;/a&gt;.&lt;/p&gt;</description></item><item><title>Terms of use.</title><link>https://battalion.energy/terms/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/terms/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / THE SITE&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Information, not an offer.&lt;/h2&gt;&#10; The content on this site describes Battalion Energy&amp;rsquo;s products and services in general terms. It is not an offer, a quotation, a specification or engineering advice for any particular project. Figures given as design bases, class values or simulation results describe the platform and its design approach. Project values are set in a written proposal or contract.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;02 / NO WARRANTY&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;The site is provided as is.&lt;/h2&gt;&#10; We work to keep the site accurate and available but give no warranty that it is error-free, complete or uninterrupted. To the extent permitted by law, Battalion Energy is not liable for loss arising from use of the site or reliance on its content.&#10; &#10; &#10; &#10; &lt;/div&gt;&#10;&lt;/section&gt;&#10;&#10;&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;03 / CONTENT AND MARKS&lt;/p&gt;</description></item><item><title>We design and control batteries for AI data centers.</title><link>https://battalion.energy/company/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/company/</guid><description>&lt;p&gt;Battalion was founded by people who had spent their careers in energy storage, utility software, remote monitoring, and automation and controls. We had operated enough battery systems, and worked around enough of the EMS products on the market, to know what they got wrong. So we built our own, from the ground up. The result is a next-generation platform that our customers tell us is exceptional, and a team that people like working with.&lt;/p&gt;</description></item><item><title>Why Battalion. One team across the system.</title><link>https://battalion.energy/why-battalion/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://battalion.energy/why-battalion/</guid><description>&lt;section class="editorial-row wrap"&gt;&#10; &lt;p class="eyebrow"&gt;01 / CONTROL&lt;/p&gt;&#10; &lt;div class="editorial-copy"&gt;&#10; &lt;h2&gt;Control at the speed of the load.&lt;/h2&gt;&#10; &lt;p&gt;The medium-voltage uninterruptible power supply (UPS) uses local block control. The UPS block controller takes 4,800 samples per second, decides in under 1 ms, with a 3 ms total response from measurement through command to the converter. On the dual-conversion path, transfer time is 0 ms because the load never leaves the inverter.&lt;/p&gt;&#10;&lt;p&gt;Every block runs local control and keeps serving load if the energy management system (EMS), the core network or the wide area network (WAN) is lost. &lt;a href="https://battalion.energy/products/ems/"&gt;Battalion EMS&lt;/a&gt; coordinates dispatch with a supervisory loop that runs once per second. Each UPS block maintains local control of its load.&lt;/p&gt;</description></item></channel></rss>